What is Continuity Testing? (Part 2)
Jun 09, 2021 Season 1 Episode 13
E&S Grounding Solutions

In this episode, E&S Grounding Solutions President David Stockin builds upon the previous episode’s discussion on testing the continuity of a grounding system, this time focusing on the clamp-on method. In this method, the clamp-on meter will induce a current on the system in two directions. The clamp-on meter can then determine the resistance. Normally, a low resistance reading will indicate that there is a good continuous loop between the grounded object under test and the larger grounding system. However, in the case of isolated grounds, the desired resistance measurement on the clamp-on meter would be extremely high (open) to indicate that current only traveled successfully in one direction. Then, a two-point test can be used to validate that there is a continuous path for the isolated ground.  A clamp-on meter can provide key insights into possible issues such as leakage current and corrosion.
 For a video of this podcast, please visit our YouTube Channel at E&S Grounding Solutions. For more information or to sign up for some of our world-renowned educational classes, please visit our website at www.ESgrounding.com

Please follow us on Social Media for updates and behind the scenes info:
Instagram:
@AskTheGroundingExperts
@ESgrounding

Facebook:
https://www.facebook.com/esgrounding

YouTube:
https://www.youtube.com/channel/UCWWjcaK6ozQI5DCF0wf58HQ

Show Notes

In this episode, E&S Grounding Solutions President David Stockin builds upon the previous episode’s discussion on testing the continuity of a grounding system, this time focusing on the clamp-on method. In this method, the clamp-on meter will induce a current on the system in two directions. The clamp-on meter can then determine the resistance. Normally, a low resistance reading will indicate that there is a good continuous loop between the grounded object under test and the larger grounding system. However, in the case of isolated grounds, the desired resistance measurement on the clamp-on meter would be extremely high (open) to indicate that current only traveled successfully in one direction. Then, a two-point test can be used to validate that there is a continuous path for the isolated ground.  A clamp-on meter can provide key insights into possible issues such as leakage current and corrosion.
 For a video of this podcast, please visit our YouTube Channel at E&S Grounding Solutions. For more information or to sign up for some of our world-renowned educational classes, please visit our website at www.ESgrounding.com

Please follow us on Social Media for updates and behind the scenes info:
Instagram:
@AskTheGroundingExperts
@ESgrounding

Facebook:
https://www.facebook.com/esgrounding

YouTube:
https://www.youtube.com/channel/UCWWjcaK6ozQI5DCF0wf58HQ